This product must be used in accordance to the following directions by HVACR professionals only.
DIRECTIONS FOR USE IN ICE MACHINES AND COFFEE BREWERS
1. Leave ice machine pump in operation but turn off refrigeration.
2. Drain unit and refill with fresh water.
3. Add Liquid Ice Machine Cleaner to water in unit. Use 8 fluid ounces for up to 3 gallons of water, or one fluid ounce of product for every 48 fl. oz. (3 pints) of water.
4. Allow cleaner to circulate for about 30 minutes. If solution does not contact all scaled surfaces use a brush to get cleaning solution to those parts. If scale is extra heavy, another dose of cleaner may be necessary. Ice machine drums may be cleaned by adding bottle of cleaner to a glass or plastic container holding two quarts of water and brushing the solution on the scaled surfaces.
5. After scale has been removed, drain out all the water and flush thoroughly with fresh water.
NOTE: DO NOT use on nickel plated or galvanized surfaces. On these surfaces, you should use Nu-Calgon’s Nickel-Safe Ice Machine Cleaner. Do not mix with chlorine bleach.